{"id":3243,"date":"2025-10-18T07:12:06","date_gmt":"2025-10-18T07:12:06","guid":{"rendered":"https:\/\/aps-eb.de\/?p=3243"},"modified":"2026-02-12T14:05:52","modified_gmt":"2026-02-12T14:05:52","slug":"oelanalyse-richtig-lesen-so-triffst-du-kluge-wartungsentscheidungen","status":"publish","type":"post","link":"https:\/\/www.aps-eb.de\/en\/oelanalyse-richtig-lesen-so-triffst-du-kluge-wartungsentscheidungen\/","title":{"rendered":"Read oil analysis correctly \u2013 how to make smart maintenance decisions"},"content":{"rendered":"<article class=\"aps-article\"><header>\n<p class=\"lede\"><strong>Summary:<\/strong> A single oil analysis is a snapshot. <strong>The trend decides<\/strong>.<br>Pay attention <em>Wear metals<\/em>, <em>Fuel dilution<\/em>, <em>silica<\/em>, <em>viscosity<\/em>,<br><em>Water\/glycol<\/em> and <em>Acid\/base numbers (TAN\/TBN)<\/em>. In case of anomalies: narrow down the cause, check in a targeted manner,<br>re-sampling after a short period of time.<\/p>\n<\/header>\n<section id=\"warum\">\n<h2>Why oil analysis makes sense for ELA1 pilots<\/h2>\n<ul>\n<li>Early detection of bearing, cylinder and valve wear.<\/li>\n<li>Evaluation of the <strong>Operating mode<\/strong> (cold run, high DA\/heat, \u2018lean of peak\u2019, Mogas\/Avgas).<\/li>\n<li>Well-founded <strong>TBO\/On-Condition Decisions<\/strong> \u2013 Trends are evidence.<\/li>\n<li>Measure the effectiveness of interventions (time of ignition, prop balance, ring change).<\/li>\n<\/ul>\n<\/section>\n<section id=\"probe\">\n<h2>How to Take a Usable Sample<\/h2>\n<ol>\n<li><strong>Warming up<\/strong> (&gt; 70 \u00b0C), sample directly after parking.<\/li>\n<li>When leaving it <strong>Middle beam<\/strong> catch (not first\/last drops).<\/li>\n<li>Clean laboratory bottle, gloves; Funnels only <strong>unique<\/strong>.<\/li>\n<li><strong>Flight Hours, Oil Type\/Brand, Refill Quantity<\/strong> indicate on the form.<\/li>\n<li>At the latest after <strong>48 h<\/strong> send.<\/li>\n<\/ol>\n<p class=\"tip\">Tip: Always <strong>The same laboratory<\/strong> and <strong>The same oil<\/strong> use \u2013 this cleans up trends.<\/p>\n<\/section>\n<section id=\"werte\">\n<h2>Key metrics \u2013 briefly explained<\/h2>\n<div class=\"table-wrap\">\n<table>\n<thead>\n<tr>\n<th>block<\/th>\n<th>Typical parameters<\/th>\n<th>An increase means<\/th>\n<th>Check immediately<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Wear metals<\/strong><\/td>\n<td>Fe, Cr, Ni, Al, Cu, Sn, Pb<\/td>\n<td><strong>Fe<\/strong> Steel\/Courses \u00b7 <strong>Cr\/Ni<\/strong> Rings\/Valves \u00b7 <strong>Al<\/strong> Pistons \u00b7 <strong>Cu\/Sn<\/strong> Bearing\/bronze \u00b7 <strong>Pb<\/strong> Bearing\/AvGas residue<\/td>\n<td>Compression\/leak-down, endoscopy, slicing oil filter<\/td>\n<\/tr>\n<tr>\n<td><strong>contaminants<\/strong><\/td>\n<td>Si, Insolubles, Ash<\/td>\n<td><strong>Si<\/strong> = dust \/ dirt \u2192 intake air \/ leaks<\/td>\n<td>Air filters, intake pipes, hoses\/clamps<\/td>\n<\/tr>\n<tr>\n<td><strong>Fuel &amp; Water<\/strong><\/td>\n<td>Fuel dilution %, Water\/glycol<\/td>\n<td>Fuel dilutes oil (cold run, rich operation); Glycol in liquid-cooled Rotax<\/td>\n<td>Cold start\/hot run, carburettor\/EFI, cooling circuit<\/td>\n<\/tr>\n<tr>\n<td><strong>Oil condition<\/strong><\/td>\n<td>Viscosity 40\/100 \u00b0C, TAN, TBN<\/td>\n<td><strong>Viscosity \u2193<\/strong> Fuel\/Wear \u00b7 <strong>TAN \u2191<\/strong> Ageing\/corrosion \u00b7 <strong>TBN \u2193<\/strong> Additives consumed<\/td>\n<td>Interval, operating profile, venting<\/td>\n<\/tr>\n<tr>\n<td><strong>additive<\/strong><\/td>\n<td>Ca\/Mg\/Zn\/P<\/td>\n<td>Varies per oil; Jumps = oil change\/top-up<\/td>\n<td>Match history<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><em>Limit values are model- and laboratory-specific \u2013 more important than absolute numbers is the <strong>Comparison with Your Predictions<\/strong>.<\/em><\/p>\n<\/section>\n<section id=\"lesen\">\n<h2>Read lab report - in 5 steps<\/h2>\n<ol>\n<li><strong>Plausibility check:<\/strong> Oil type, runtime (h\/day), refill quantity.<\/li>\n<li><strong>Trend view:<\/strong> Comparison with 3-5 previous samples (similar runtime!).<\/li>\n<li><strong>Cluster:<\/strong> Do e.g. Fe + Cr + Ni rise together? \u2192 friction partner\/cylinder.<\/li>\n<li><strong>Assign source:<\/strong> Use the table above (Pb+Sn \u2192 Stock, etc.).<\/li>\n<li><strong>Action &amp; Re-Test:<\/strong> define the measure, in <strong>10-25 h<\/strong> Sampling again.<\/li>\n<\/ol>\n<\/section>\n<section id=\"faelle\">\n<h2>Typical findings &amp; what you do<\/h2>\n<ul>\n<li><strong>Fe \u2191 + Cr moderate \u2191, Viscosity \u2193<\/strong> \u2192 Friction + fuel dilution.<br><em>Action:<\/em> Test mixture\/run-up, avoid cold running, oil change, re-test 15-20 h.<\/li>\n<li><strong>Si clear \u2191 + Al easy \u2191<\/strong> \u2192 dust; React piston\/raceway.<br><em>Action:<\/em> Air filter\/seal suction, endoscopy, re-test.<\/li>\n<li><strong>Cu + Sn \u2191, Pb \u2191<\/strong> \u2192 bearing\/bronze; Possibly AvGas effect.<br><em>Action:<\/em> Cut open oil filter, check vibration\/ignition, leak-down.<\/li>\n<li><strong>Fuel dilution &gt; 2\u20133\u00a0%<\/strong> or <strong>Viscosity strong \u2193<\/strong> \u2192 a lot of short distance\/rich.<br><em>Action:<\/em> Adjust operating profile, carburettor\/EFI setting, short interval.<\/li>\n<li><strong>TAN \u2191 + Insolubles \u2191<\/strong> \u2192 Oil ages\/humidity\/maintenance.<br><em>Action:<\/em> Interval shortening, dehumidification, longer warm runs, winter preservation.<\/li>\n<\/ul>\n<p><strong>Rotax Note (912\/914\/915):<\/strong> AvGas share &gt; 30\u00a0% increases the need for maintenance; The interval between 25 and 50 h. Burp procedure and clean sampling are essential.<\/p>\n<\/section>\n<section id=\"matrix\">\n<h2>Decision Matrix (simplified)<\/h2>\n<ul>\n<li><strong>Single, slight abnormality<\/strong> (without trend) \u2192 continue flying, re-test in 15-25 h.<\/li>\n<li><strong>Several metals rise together<\/strong> \u2192 Additional checks (compression\/endoscope\/filter cut), short interval, re-test.<\/li>\n<li><strong>Strong jump + symptoms<\/strong> (vibration, oil consumption, metal in the filter) \u2192 ASAP workshop diagnosis.<\/li>\n<li><strong>Glycol\/water detectable<\/strong> \u2192 fly no further, fix cause.<\/li>\n<\/ul>\n<\/section>\n<section id=\"hangar\">\n<h2>From the hangar<\/h2>\n<ul>\n<li><strong>Prop balances:<\/strong> Fe\/Cr trend flattens, CHT spread improves \u2192 measurable effect.<\/li>\n<li><strong>Leaky intake gasket:<\/strong> Si peak in two samples; Normalized after gasket replacement.<\/li>\n<li><strong>Training organisation:<\/strong> High fuel dilution + low viscosity; Profile adjusted \u2192 values stable.<\/li>\n<\/ul>\n<\/section>\n<section id=\"checkliste\"><\/section>\n<section id=\"faq\">\n<h2>FAQs<\/h2>\n<p><strong>How often do you sample?<\/strong> At least for oil change; additionally after interventions or in case of abnormalities early.<\/p>\n<p><strong>Which runtime per sample?<\/strong> As constant as possible (e.g. 40-50 h), otherwise trends are difficult to compare.<\/p>\n<p><strong>When is a value \u2018too high\u2019?<\/strong> If it runs against your trend or multiple partners rise together. Laboratory flags are clues, not judgments.<\/p>\n<\/section>\n<aside class=\"cta\">\n<h3>Questions about your lab report?<\/h3>\n<p>We help with the classification and plan the next steps with you (filter cut, leak-down, endoscopy, test flight).<\/p>\n<\/aside>\n<\/article>\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Summary: A single oil analysis is a snapshot \u2013 the trend decides.Take care of wear metals, fuel dilution, silicon, viscosity, water\/glycol and acid\/base numbers<\/p>","protected":false},"author":1,"featured_media":3246,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_rtcl_gb_attr":"","ngg_post_thumbnail":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[341],"tags":[379,378,376,375,377],"class_list":["post-3243","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tips-tricks","tag-continental","tag-lycoming","tag-motor","tag-oelanalyse","tag-rotax"],"jetpack_featured_media_url":"https:\/\/www.aps-eb.de\/wp-content\/uploads\/2025\/10\/Oelanalyse.webp","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.aps-eb.de\/en\/wp-json\/wp\/v2\/posts\/3243","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aps-eb.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.aps-eb.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.aps-eb.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aps-eb.de\/en\/wp-json\/wp\/v2\/comments?post=3243"}],"version-history":[{"count":1,"href":"https:\/\/www.aps-eb.de\/en\/wp-json\/wp\/v2\/posts\/3243\/revisions"}],"predecessor-version":[{"id":20839,"href":"https:\/\/www.aps-eb.de\/en\/wp-json\/wp\/v2\/posts\/3243\/revisions\/20839"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.aps-eb.de\/en\/wp-json\/wp\/v2\/media\/3246"}],"wp:attachment":[{"href":"https:\/\/www.aps-eb.de\/en\/wp-json\/wp\/v2\/media?parent=3243"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.aps-eb.de\/en\/wp-json\/wp\/v2\/categories?post=3243"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.aps-eb.de\/en\/wp-json\/wp\/v2\/tags?post=3243"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}